Smart Multi-Function Meter EIPL56ER

Smart Multifunction Meters are based on 32 Bit, 100 Pin Microprocessor, with 24 Bit Six Channel Sigma Delta Front end Analog to Digital Converters. The measurement accuracy of Class 0.5 can be achieved on the practical range of operation.

product-rotate-img
product-rotate-img
product-rotate-img
product-rotate-img
product-rotate-img
product-rotate-img
product-rotate-img

Click for 360° View

icon

32 Bit 100 Pin Powerful Processor

gprs1
icon

Bi-Directiona

gprs1
icon

Four Quadrant Reactive Energy

gprs1
product-rotate-img
icon gprs4

Class 0.5S Accuracy

icon gprs5

RS-485 port communicates as per MODBUS Protocol

icon gprs5

Energy Pulse Output

Specifications

  • Smart Multifunction Meters are based on 32 Bit, 100 Pin Microprocessor, with 24 Bit Six Channel Sigma Delta Front end Analog to Digital Converters. The measurement accuracy of Class 0.5 can be achieved on the practical range of operation.
  • Programmable Multifunction Meters is a versatile instrument used for controlling the electricity consumption and is extremely useful for putting up a limit on the drawn load. This instrument can also be used in various applications with controlled load options.
  • The variants available are

    TMFLR70 - Smart MF LCD Meter Cl - 05.S

    EIPL720CR - Smart MF LCD Meter Cl - 0.2S

    TMFR42 - Advance MF 7 Segment Meter Cl - 1.0

    TMF28 - Basic MF 7 Segment Meter Cl - 1.0

Key Features

  • 0.5S Class Accuracy of Active Energy
  • 32 Bit, 100 Pin, Processor
  • SMT Technology
  • 7 Segment Bright LED Display
  • 1 Energy Pulse Output
  • RS 485 interface (Modbus-RTU)
  • Various choice of Bright LED display
  • Bi-directional Energy
  • Four-Quadrant reactive energy
  • Total Harmonic Distortion (THD)
  • Real Time Measurement of Demand

DPM is a device which measures the values of ELECTRICAL Parameters

1) Hi Accuracy
2) Micro Designed
3) Easy to Read Display
4) Automatic Reading

There are 3 main parameters in electricity measurements and the DPM captures the parameters through transducers and then runs an algorithim in microprocessor and dispays accurate value of parameter

1) Accurate Measurement of Electric system
2) Protection and Sitch gear calculation for stopping any accidents
3) Energy Auditing
4) Billing for Energy
5) SCADA

PROS of DPM
1. More Accurate then Analog Counterparts
2. Automatic Meter reading can be configured
3. Power Analysis , Harmonics , Auditing
4. More Reliable ove a period of Time
5. No Regular Calibration Required
6. Maintenance Free

CONS of DPM
1. Higher Pricing then the Analog counterpart

YES

YES